Quick answer

Record a dated opening and closing reading from the same electricity import register, then divide the period’s kWh by its number of days. Keep actual and estimated readings distinct, and note changes such as EV charging or solar panels. Use the private register and fictional example below. This is an electricity-recording guide, not a bill forecast or resident study result; the website collects no readings.

Start with one complete period

Download the blank electricity-use register (CSV). Keep it on your own device. Begin with the dates, reading values, register name and whether each value is actual or estimated; add context as it becomes useful.

This records electricity imported from the grid, not all the costs of running a home. Tariffs, fixed charges, insurance, maintenance and mortgage payments answer different questions. If you have not yet established the right account or opening reading, use the electricity setup guide first.

Choose readings you can compare

Use the same cumulative import register at the start and end. Keep its label with the values, especially where a meter displays several registers. Record the units: this calculation uses kWh, not the instantaneous power in kW.

  • Save the reading date and time and a private evidence reference.
  • Mark estimated values clearly; replace them when a suitable actual reading is available.
  • If the meter was exchanged or reset, reconcile the separate periods before subtracting.
  • With day/night or other registers, add only non-overlapping import amounts. Do not add a total to its own components.

Do not open equipment or remove covers to get a reading. Use the normal meter display or supplier record; ask your supplier or ESB Networks if you cannot identify it safely.

A fictional completed example

These invented numbers demonstrate the arithmetic. They are not measured household results, a target or a forecast.

Field Fictional entry
Period 1 September to 1 October 2026: 30 days
Register Same cumulative electricity-import register
Opening / closing reading 1,250 kWh / 1,850 kWh; both actual
Period electricity 1,850 − 1,250 = 600 kWh
Average per day 600 ÷ 30 = 20 kWh/day
Context Fictional example only; no real home or occupancy data

kWh per day = period import kWh ÷ days in the period

Retain the original values so you can check the calculation later. A bill total alone cannot show whether a change came from consumption, the tariff or fixed charges.

Add enough context to explain a change

For your own comparison, note the home type, period, BER label, broad occupancy context and substantial changes to heating, hot water or other loads. Keep names and detailed daily routines out of anything you share.

EV charging can add electricity demand. Solar PV and a battery can change grid import without producing the same change in total household use. Other fuels matter too. Compare similar seasons and explain missing days or changed circumstances.

SEAI explains that BER uses standard assumptions rather than measured household consumption. Treat the rating as context, not a bill prediction.

What the record cannot tell you

Do not multiply one winter month into a claimed measured annual figure. Whole-home electricity alone does not measure heat-pump efficiency: that also needs an appropriate heat-measurement boundary. SEAI’s maintenance guide, section 3, distinguishes electricity and heat measurement; its larger-system maintenance regime is not a domestic service schedule.

If usage changes unexpectedly, check dates, estimates, register selection and changed loads first. Use the first-winter guide for a useful observation record and reasons to contact the installer. These calculations do not diagnose a fault.

Keep the file private

The site has no reading-submission form. Do not email bills, meter photos, MPRNs, account numbers, addresses or identifying filenames as a contribution. Codes replacing names may still leave a household identifiable, as the Data Protection Commission explains.

A possible future Dublin 18 study would need permissioned contributions, a transparent sample and disclosure checks. Its proposed study protocol (Markdown) is supporting material; no recruitment or resident findings are available now.

Start with one electricity period

Keep the blank record privately. Label actual and estimated readings and use the same import register at both ends.

Download electricity-use registerAbout Kinrota — launching soon

Common questions

Does this show typical electricity use for Dublin 18?

No. The example is fictional. No resident sample or local average is reported, and a single home or month cannot establish one.

Can I send my bill or completed register to take part?

No study is recruiting here. Keep your file privately. Any future collection needs its own research and privacy arrangements before contributions are requested.

Sources

  1. BER: calculated and measured consumption · SEAI · checked 21 October 2026
  2. Heat Pumps: Operation and Maintenance Guide, section 3 · SEAI · checked 21 October 2026
  3. Anonymisation and pseudonymisation · Data Protection Commission · checked 21 October 2026

Researched and edited by Kinrota. Report an outdated detail with the page link and a public source. Keep private documents, addresses and account details out of your message.

This is general information, not professional advice. Always check the source and your own contracts, manuals and circumstances.