Which unit do you have?
The developer’s house brochure describes heat recovery ventilation (HRV): continuous extraction from wet rooms and filtered supply to bedrooms and living rooms. MVHR is mechanical ventilation with heat recovery. The brochure does not identify every installed model.
Local tip · resident reportUnverified resident reports mention attic-mounted Vent-Axia Sentinel Kinetic B and Plus units, stiff filter flaps and residents' association filter orders. Household/phase coverage, sample size and dates were not recorded. Check your label; ask whether an order is currently available. Do not force a stuck flap—ask the installer/developer for help.
The apartment specification lists Dimplex and NIBE exhaust-air heat-pump versions; confirm the system actually installed in your home. Do not assume a house’s separate Vent-Axia instructions apply to your apartment.
Filter references by model
Manual 442073’s spares table (page 19) gives these references. The B/BH pollen-filter page identifies its M5 option as a single supply filter.
| Model on your label | G3 pair | M5 supply filter |
|---|---|---|
| Sentinel Kinetic B or BH | 442356 | 444199 |
| Sentinel Kinetic F or FH | 409764 | 472153 |
| Sentinel Kinetic Plus or High Flow | 403702 | 444201 |
Confirm compatibility and any superseded references using Find your filter. Match the full unit model, not appearance alone.
Safe filter care and reset
For units covered by user manual 442073, pages 8 and 17:
- Arrange safe access. Isolate the fan and ancillary control equipment from their power supplies, using the installation’s designated isolator(s). If you cannot confirm isolation or safely reach the unit, stop and use a ventilation engineer. Do not work on wiring or remove covers.
- With power isolated, open only the filter flaps. Remove both filters and gently tap or carefully vacuum them; fit suitable replacements if necessary.
- Refit the filters and close both flaps before restoring power.
- Restore power at the isolator(s). On the controller, hold Up + Down for five seconds; at Reset Filter?, press Set to confirm.
The timer is set during installation. Page 2 advises monthly filter checks for the first six months of a new build. Other models’ schedules can differ: follow your own manual. Leave heat-exchanger, internal and electrical maintenance to professionals.
Boost, purge and summer bypass
- Control Mode 01 only: successive presses of the controller’s boost button select 30 minutes, 60 minutes, continuous boost, then normal. Holding it for five seconds starts purge; hold again to cancel.
- Control Mode 02 differs: use Appendix One (page 21) for its sequence. If unsure which mode is installed, ask the installer. Do not change control mode or commissioned airflow settings to match this guide.
- Summer bypass, where fitted: cooler outdoor air can bypass heat recovery when temperature conditions allow. The manual describes Normal, Evening Purge and Night-time Purge options; this does not provide active air conditioning. Ask the installer about your settings rather than changing commissioning values.
Common questions
How do I clear the "Check Filter" message?
For manual 442073 units, first isolate the fan and ancillary controls safely, clean/refit the filters and close the flaps. Restore power, hold Up + Down for five seconds, then confirm with Set. Use an engineer if access or isolation is uncertain.
Why does the reminder return when the filters look clean?
It follows a timer, not measured dirt. Follow the maintenance schedule in your own model's instructions; reset after checking/cleaning, not instead of it.
Which filters do I order?
Match the full model label to the table and Vent-Axia's current filter finder. The G3 references are pairs; the M5 references are single supply filters. A neighbour's filter may not fit.
Can I wash the filters?
The linked user manual specifies gentle tapping or careful vacuuming. It does not give washing instructions. Replace a filter that remains clogged or is damaged, using the correct model reference.
Related answers
- Daikin heat pump in Clay Farm: service dates and warranty records
- Your first year in Clay Farm: snags, pump, heat pump and filters by month
- Finding a plumber or tradesperson for a Clay Farm home
Sources
Local tips are resident reports. Their household/phase coverage, sample sizes and observation dates were not recorded. Official-source checked dates do not date those observations. Confirm your own model, calendar or aftercare terms.
- Sentinel Kinetic MVHR range user instructions (442073 AB, September 2025) · Vent-Axia (manufacturer) · checked 22 October 2026
- Lo-Carbon Sentinel Kinetic B (product page and documents) · Vent-Axia (manufacturer) · checked 22 October 2026
- Sentinel Kinetic B/BH ISO ePM10 50% (M5) pollen filter · Vent-Axia (manufacturer) · checked 22 October 2026
- Find your filter · Vent-Axia (manufacturer) · checked 22 October 2026
- Clay Farm house launch brochure (April 2025 update) · Park Developments (developer) · checked 22 October 2026
- Apartment specification · Park Developments (developer) · checked 22 October 2026
Researched and edited by Kinrota. Report an outdated detail with the page link and a public source. Keep private documents, addresses and account details out of your message.
This is general information, not professional advice. Always check the source and your own contracts, manuals and circumstances.